Commercial Reverse Osmosis Unit

Commercial Reverse Osmosis Unit

Commercial reverse osmosis unit

Commercial Reverse Osmosis Unit

Light commercial reverse osmosis unit

Reverse Osmosis Unit (R.O)

  • LIGHT COMMERCIAL R.O UNIT : Production capacity: 300 GPD, 450 GPD, 600 GPD, 900 GPD
  • COMMERCIAL R.O UNIT : Production capacity: 1100 GPD, 2500 GPD, 5000 GPD, 10000 GPD
  • Water filtration system : RO filter, NANO filter, Ultrafiltration, Microfiltration, UV sterilizer.

Commercial Reverse Osmosis Unit. high quality, reliable RO systems

Affordable for any application size from small to large scale commercial.

Light Commercial Reverse Osmosis Unit

Commercial Reverse Osmosis Unit
Commercial Reverse Osmosis Unit
Model
RO-300
RO-450
RO-600
RO-900
Production capacity (GPD: Gallon Per Day) 300 GPD 450 GPD 600 GPD 900 GPD
Electricity 110/220 Vac 110/220 Vac 110/220 Vac 110/220 Vac
Power consumption 230 W 230 W 450 W 450 W
Number of TFC R.O membrane (150 GPD) 2 3 4 6
Automatic flush membrane Yes Yes Yes Yes
Feed water required (Minimum, PSI) 5 PSI 5 PSI 15 PSI 15 PSI
Operation pressure 60-80 PSI 60-80 PSI 60-80 PSI 60-80 PSI

Commercial Reverse Osmosis Unit

Commercial Reverse Osmosis Unit
Commercial Reverse Osmosis Unit
Model
RO-1100
RO-2500
RO-5000
RO-10000
Production capacity (GPD: Gallon Per Day) 1100 GPD 2500 GPD 5000 GPD 10000 GPD
Electricity 110/220 Vac 110/220 Vac 110/220 Vac 110/220 Vac
Power consumption 260 W 570 W 1130 W 3000 W-3P
Low/High pressure cut-off switch Yes Yes Yes Yes
Permeate / Concentrate flow meter Yes Yes Yes Yes
Stainless steel frame Yes Yes Yes Yes
Number of TFC R.O membrane 2.5″ x 40″, 1 4″ x 40″, 1 4″ x 40″, 2 4″ x 40″, 4
Automatic flush membrane Yes Yes Yes Yes
Feed water required (Minimum, PSI) 45 PSI 45 PSI 45 PSI 45 PSI
Operation pressure 100-120 PSI 100-120 PSI 100-120 PSI 100-120 PSI

Professional Reverted osmosis 60 liters hour – 1440 liters per day

Small flows water treatment

Whether it is rainwater or from wells and drilling – even to provide sterilization complementary to the water of a public network.

  • In/out 1/2″ female NPT.
  • Power: 220 VAC; 50 Hz
  • Consumption: 140 Watts (max.)
  • Water discharge: 50-50
  • Feed water requirements: 5 litres/minute at 1 bar
  • 1 – 25 micron sediment filter, 2.5×20 cartridge.
  • 1 – 5 micron activated charcoal block filter, 2.5×20 cartridge.
  • 1 – 1 micron sediment filter, 2.5×20 cartridge.
  • Booster Pump 24 VDC; 6 A
  • 1 low pressure switch
  • Three membranes TFC R.O, 2.5″ x 12″
  • A solenoid valve
  • 24 VDC power supply
  • A flushing solenoid valve, 24 VDC
  • A concentrated valve
  • A recycling valve
  • Water pressure gauges
  • A diet
  • Painted steel structure.
  • Dimension 81 x 45 x 21 cm